Pump-Free Supercritical CO₂ Extractors - ANTON & EASYONE
Discover TENNAD's range of pump-free supercritical CO₂ extractors for research, testing, training and laboratory-scale feasibility studies: ANTON 100 mL / 150 bar, EASYONE 125–250 mL / 350 bar and EASYONE 500 mL / 350 bar. These compact systems make it possible to explore supercritical CO₂ extraction using small quantities of raw material, in a format suitable for laboratories, R&D centers, universities and innovation teams.
125–250 mL
350 bar
EASYONE 125–250 mL
Automatic, screening, feasibility studies and sample preparation
500 mL
350 bar
EASYONE 500 mL
Automatic, compact, research and laboratory-scale testing
A range of compact supercritical CO₂ extractors for the laboratory
TENNAD offers several extraction volumes to cover initial evaluations using very small quantities of material, educational demonstrations, pressure/temperature screening, feasibility studies and process development. ANTON focuses on mobility, process visibility and ease of use, while the EASYONE range provides precise automated operation for reproducible and structured laboratory testing.
ANTON 100 mL Supercritical CO₂ Extractor
ANTON is a compact 100 mL supercritical CO₂ extractor designed and manufactured by TENNAD for testing, demonstrations, sourcing activities, training and R&D.
The ANTON extractor is a 100 mL supercritical CO₂ extraction unit designed and manufactured by TENNAD. Compact, easy to move and simple to operate, it is ideal for sourcing activities, research laboratories, showrooms and training sessions when genuine extracts need to be obtained quickly from small quantities of raw material.
By using CO₂ as a green solvent, ANTON makes it possible to obtain concentrated aromas, essential oils and active compounds while preserving the character of the original plant material. Temperature or pressure can be adjusted to protect delicate molecules.
The extractor is equipped with a transparent cylindrical sapphire body providing 360° visibility of the extraction chamber. This complete visibility makes it possible to observe in real time what is happening inside the extractor, including the transition to the supercritical phase. With its 100 mL volume and intuitive operation, ANTON is particularly suitable for education and hands-on training in supercritical CO₂ extraction.
- 100 mL extraction vessel for rapid testing and small batches
- Maximum operating pressure up to 150 bar
- Temperature range from +20 °C to +150 °C
- Operates with CO₂ and a co-solvent to enhance extraction power
- Designed for mobility between sourcing sites, pilot laboratories and training rooms
ANTON 100 mL extractor
Bring extraction closer to your raw materials
Thanks to its compact design and 100 mL extraction volume, ANTON makes it possible to carry out supercritical CO₂ extraction as close as possible to the sourcing or production site. Instead of sending fragile plant materials to a distant laboratory, tests can be performed shortly after harvesting and different origins or batches can be compared directly.
- On-site evaluation: quickly assess new plant materials or new suppliers.
- Laboratory screening: perform feasibility studies and parameter optimization before scale-up.
- Demonstrations and training: present the supercritical CO₂ process in a clear and educational way.
- Innovation & R&D: explore new extracts and fractions using minimal amounts of raw material.
Stand-alone and mobile operation
The ANTON extractor is designed to operate easily with standard laboratory equipment while remaining self-contained and easy to move.
- Can be placed directly on a standard laboratory heating magnetic stirrer.
- Operates with a magnetic stir bar inside the vessel, providing effective mixing of the components in supercritical CO₂.
- Can be equipped with a 0 °C to +150 °C temperature probe connected to a portable digital indicator.
- The temperature reader is battery-powered and fully independent, allowing operation without an external electrical power supply for the reader.
Combined with its compact format, 360° visual access and compatibility with common laboratory stirrers, these features make ANTON a highly mobile extractor particularly suitable for demonstrations, training sessions and rapid extraction campaigns.
ANTON extractor on a heating magnetic stirrer
Supercritical CO₂ for aroma and fragrance extraction
High-quality extracts using a green solvent
Supercritical CO₂ combines the diffusion properties of a gas with the solvent power of a liquid. By adjusting pressure and temperature, specific families of molecules can be targeted without using petrochemical solvents.
- No toxic solvent residues in the final extract
- Suitable for heat-sensitive compounds
- Compatible with a co-solvent to broaden the range of extractable molecules
Who is ANTON designed for?
ANTON is designed for organizations that need flexible small-scale supercritical CO₂ extraction capabilities:
- Perfumery & cosmetics: on-site aroma capture, sourcing validation and concept development.
- Food & beverages: extraction of aromas, spices, coffee and tea fractions or functional ingredients.
- Research & universities: hands-on teaching of phase behavior and green extraction techniques with direct process visibility.
- Innovation hubs & demonstration laboratories: presentation of sustainable extraction technologies to visitors and partners.
EASYONE 125–250 mL / 350 bar Supercritical CO₂ Extractor
EASYONE extractors are 100 % automatic, compact and designed for research, rapid evaluation of extraction parameters, sample preparation and laboratory-scale feasibility studies.
The EASYONE extractor is a compact and fully self-contained supercritical CO₂ extraction system. Designed and manufactured by TENNAD, it provides a simple and accessible approach to exploring CO₂ extraction for teaching and research.
EASYONE automatically controls pressure, temperature and extraction time, making it possible to compare extraction conditions, assess selectivity and identify suitable parameters for a given biomass.
Unlike conventional dynamic extraction systems, EASYONE is designed for pump-free static supercritical extraction. It can be used for feasibility studies, pressure/temperature screening, solubility testing and sample preparation on a compact and automatic machine.
- 100 % automatic R&D extractor for simplified supercritical CO₂ testing
- Precise and automatic control of pressure, temperature and extraction time
- Intuitive touchscreen HMI for operation and process monitoring
- Usable basket volumes: 125 mL or 250 mL
- Operating pressure up to 350 bar
- Temperature up to 95 °C
- Automatic cleaning cycle to simplify routine operation
EASYONE extractor – compact automatic R&D system
EASYONE 125 mL / 250 mL extractor
Precise control for rapid evaluation of extraction parameters
EASYONE is designed to rapidly screen pressure and temperature conditions and compare the selectivity of different extraction parameters. The user defines pressure, temperature and extraction time, then starts the process from the touchscreen interface.
EASYONE is particularly useful for comparing natural matrices, evaluating aroma profiles, optimizing extraction parameters or validating the feasibility of a future supercritical CO₂ process before scaling up.
- Rapid P/T screening: compare different pressure/temperature combinations.
- Reproducible testing: perform controlled experiments under defined conditions.
- Selective extraction: evaluate the influence of operating parameters on extract composition.
- Process validation: progress from initial trials to validated laboratory conditions.
Designed for laboratory-scale R&D
EASYONE combines compact dimensions, 100 % automated control and convenient laboratory operation. Its usable basket volumes of 125 mL and 250 mL are suitable for screening studies on natural raw materials while limiting sample and CO₂ consumption.
The touchscreen HMI simplifies operation and provides clear access to key process parameters. The automatic cleaning cycle helps reduce downtime between experiments and supports routine use in laboratories, universities and R&D centers.
- Compact self-contained system for teaching, analytical and research laboratories
- 125 mL or 250 mL basket configuration depending on the application
- Touchscreen interface for control and monitoring
- Automatic cleaning cycle for simplified operation
- Optimized for small sample quantities and repeated screening tests
EASYONE for R&D screening and laboratory testing
Wide range of R&D applications
EASYONE supports a wide range of exploratory and analytical applications using liquid or supercritical CO₂. It is suitable for early-stage feasibility testing, matrix comparisons and method development.
- Solubility studies under controlled CO₂ conditions
- Static supercritical CO₂ extraction for natural matrices
- Static CO₂ treatment and feasibility testing
- Maceration under liquid or supercritical CO₂ conditions
- Supercritical CO₂-assisted impregnation
- Thermal cycling and parameter comparison
- Co-solvent use according to the target compounds and application
Sample preparation before chromatographic analysis
EASYONE can also be used as a sample preparation tool before chromatographic analysis. Static supercritical CO₂ extraction can generate clean, concentrated and reproducible extracts for aroma profiling and chromatographic fingerprinting.
- Sample preparation before GC-MS, GC-FID, GC-O, HPLC or LC-MS
- Comparison of aroma profiles and chemical signatures
- Screening of raw materials, batches, origins or extraction conditions
- Generation of reproducible extracts for analytical workflows
Who is EASYONE designed for?
EASYONE is designed for organizations that need a compact, automated and reproducible approach to exploring supercritical CO₂ extraction at laboratory scale.
- Research laboratories: pressure/temperature screening, feasibility studies and preliminary testing.
- Analytical laboratories: sample preparation before chromatographic analysis.
- Universities and education: hands-on teaching of supercritical CO₂ extraction principles.
- Cosmetics and perfumery: comparison of aroma profiles and extraction selectivity.
- Food, natural ingredients and biomaterials: evaluation of matrices, extracts and process conditions.
EASYONE 500 mL / 350 bar Supercritical CO₂ Extractor
The EASYONE 500 mL / 350 bar supercritical CO₂ extractor is a compact, 100 % automatic extractor designed for research, supercritical CO₂ experiments, feasibility studies and laboratory-scale screening.
EASYONE 500 mL / 350 bar extractor
More volume for laboratory feasibility studies
The EASYONE 500 mL model completes the range with a larger extraction volume while retaining a compact and automatic design intended for research work and supercritical CO₂ testing.
- Extraction volume: 500 mL
- Operating pressure: up to 350 bar
- 100 % automatic and compact extractor
- Designed for research and supercritical CO₂ experiments
- Suitable for laboratory-scale feasibility studies and screening
Which supercritical CO₂ extractor should you choose?
For mobility, demonstrations, education, sourcing and rapid testing with very small quantities of raw material.
For automated R&D, pressure/temperature screening, feasibility studies and sample preparation.
For a larger test volume while retaining a compact automatic laboratory extractor.
Need help choosing your supercritical CO₂ extractor?
Tell us about your application, raw material,
available sample volume and extraction objectives.
The TENNAD team will help you identify the most suitable solution.