EASYONE Supercritical CO₂ Extractor
Compact automatic R&D extractor for supercritical CO₂ experiments: EasyOne, designed for fast pressure/temperature screening, sample preparation and laboratory-scale feasibility studies.
EasyOne Supercritical CO₂ Extractor
The EasyOne Extractor is a compact, fully autonomous R&D system for supercritical CO₂ experiments. Designed and manufactured by TENNAD, it provides a simple and accessible way to explore CO₂ extraction in teaching, analytical and research laboratories.
EasyOne automatically controls pressure, temperature and extraction time, allowing users to compare extraction conditions, evaluate selectivity and identify suitable parameters for a given biomass.
Unlike conventional dynamic extraction systems, EasyOne is especially suited to static and isochoric supercritical CO₂ work. It helps laboratories perform proof-of-concept studies, pressure/temperature screening, solubility testing and sample preparation with a compact and easy-to-operate platform.
- Fully automatic R&D extractor for supercritical CO₂ experiments
- Precise control of pressure, temperature and extraction time
- Touchscreen HMI for easy operation and process monitoring
- Useful biomass basket volumes: 125 mL or 250 mL
- Operating pressure up to 350 bar
- Temperature up to 95 °C
- Automatic cleaning cycle for easier routine use
EasyOne Extractor – compact automatic R&D system
Resources: photos, technical data sheets and product information
EasyOne 125 mL / 250 mL Extractor
Precise Control for Fast Screening
EasyOne is designed to quickly screen pressure and temperature conditions and compare the selectivity of different extraction parameters. The user sets the pressure, temperature and extraction time, then starts the process from the touchscreen interface.
This makes EasyOne particularly useful when the objective is to compare natural matrices, evaluate aromatic profiles, optimise extraction parameters or validate the feasibility of a future CO₂ process before moving to larger equipment.
- Fast P/T screening: compare pressure and temperature combinations quickly.
- Reproducible tests: run controlled experiments under defined conditions.
- Selective extraction: evaluate how operating parameters influence extract composition.
- Process validation: move from first trials to validated laboratory conditions.
Designed for Laboratory-Scale R&D
EasyOne combines compact dimensions, automated control and practical laboratory handling. Its 125 mL and 250 mL useful basket volumes make it suitable for screening studies on natural raw materials while limiting sample and CO₂ consumption.
The touchscreen HMI simplifies operation and gives clear access to key process parameters. The automatic cleaning cycle helps reduce downtime between experiments and supports routine use in laboratories, universities and R&D centres.
- Compact autonomous system for teaching, analytical and research laboratories
- 125 mL or 250 mL basket configuration depending on the application
- Touchscreen interface for control and monitoring
- Automatic cleaning cycle for simplified operation
- Optimised for small sample quantities and repeated screening tests
Wide Range of R&D Applications
EasyOne supports a broad range of exploratory and analytical applications using liquid or supercritical CO₂. It is suitable for early-stage feasibility testing, matrix comparison and method development.
- Solubility studies under controlled CO₂ conditions
- Static supercritical CO₂ extraction for natural matrices
- Static CO₂ treatment and feasibility testing
- Maceration under liquid or supercritical CO₂ conditions
- Supercritical CO₂-assisted impregnation
- Thermal cycling and parameter comparison
- Co-solvent use depending on the target compounds and application
EasyOne for R&D screening and laboratory trials
Sample Preparation Before Chromatographic Analysis
EasyOne can also be used as a sample preparation tool before chromatographic analysis. Static supercritical CO₂ extraction can generate clean, concentrated and reproducible extracts for aroma profiling and chemical fingerprinting.
- Sample preparation before GC-MS, GC-FID, GC-O, HPLC or LC-MS
- Comparison of aromatic profiles and chemical signatures
- Screening of raw materials, batches, origins or extraction conditions
- Generation of reproducible extracts for analytical workflows
Who Is EasyOne For?
EasyOne is designed for organisations that need a compact, automated and reproducible way to explore supercritical CO₂ extraction at laboratory scale.
- Research laboratories: pressure/temperature screening, proof-of-concept studies and feasibility tests.
- Analytical laboratories: sample preparation before chromatographic analysis.
- Universities and education: practical teaching of supercritical CO₂ extraction principles.
- Cosmetics and perfumery: comparison of aromatic profiles and extraction selectivity.
- Food, natural ingredients and biomaterials: evaluation of matrices, extracts and process conditions.
Interested in the EasyOne Extractor?
Contact the TENNAD team to discuss your supercritical CO₂ R&D project.
Contact Us